QUICK LINKS..
 
 
 
..S B ..S E R I E S ..P R I N T S
     
.SB Series Pellethane Split Repair Boots
PART NUMBER
DESCRIPTION
FITTING TYPE
Split Repair Boot that is designed to replace an existing 4 studded entry fitting
Small
Angled Split Repair Boot that is designed to replace an existing 4 studded entry fitting
Small
Split Repair Boot for applications where there is no fitting installed
Medium
Split Repair Boot for applications where there is no fitting installed
Medium
Split Repair Boot for applications where there is no fitting installed
Medium
Split Repair Boot that will encapsulate small entry fittings
Large
Split Repair Boot that will encapsulate small entry fittings
Large
Low Profile Split Repair Boot to replace an existing 8 studded entry fitting. Boot height of 2.25”
Large
Split Repair Boot that will encapsulate small entry fittings
Large
Split Repair Boot for dual supply/return lines for generator sites
Large
Low profile Split Repair Boot to replace an existing 10 studded fitting. Boot height of 2.25”
Extra Large
Split Repair Boot that will encapsulate (S) to (M) entry fittings & replace 10 studded fittings
Extra Large
Low profile Split Repair Boot to replace an existing 10 studded fitting. Boot height of 2.25”
Extra Large
Split Repair Boot that will encapsulate (S) to (M) entry fittings & replace 10 studded fittings
Extra Large
Split Repair Boot that is large enough to encapsulate most large sized entry fittings
Double Extra Large
Split Repair Boot that is large enough to encapsulate most large sized entry fittings
Double Extra Large
Split Repair Boot that is large enough to encapsulate most large sized entry fittings
Double Extra Large
.SBTCI Split Repair Boots for Total Containment Fittings
PART NUMBER
DESCRIPTION
DIMENSIONS
Split Repair Boot for Total Containment electrical conduit entry fittings 2.61x1.4
2.61x1.4
Split Repair Boot for Total Containment entry fittings. 6.8x2.0
6.8x2.0
Split Repair Boot for Total Containment entry fittings. 6.8x2.0  w/ Air Test
6.8x2.0
Split Repair Boot for Total Containment entry fittings. 6.8x2.25
6.8x2.25
Split Repair Boot for Total Containment entry fittings. 6.8x2.25  w/ Air Test
6.8x2.25
Split Repair Boot for Total Containment entry fittings. 6.8x2.5
6.8x2.5
Split Repair Boot for Total Containment entry fittings. 6.8x2.5  w/ Air Test
6.8x2.5
Split Repair Boot for Total Containment entry fittings. 6.8x2.7
6.8x2.7
Split Repair Boot for Total Containment entry fittings. 6.8x3.0
6.8x3.0
Split Repair Boot for Total Containment entry fittings. 6.8x3.0  w/ Air Test
6.8x3.0
Split Repair Boot for Total Containment entry fittings. 6.8x3.5
6.8x3.5
Split Repair Boot for Total Containment entry fittings. 6.8x3.5  w/ Air Test
6.8x3.5
Split Repair Boot for Total Containment entry fittings. 6.8x4.5
6.8x4.5
SBTCI6.8x4.5A
Split Repair Boot for Total Containment entry fittings. 6.8x4.5  w/ Air Test
6.8x4.5
     
.SBTCIF Split Repair Boots with Fill Tube for Total Containment Fittings
PART NUMBER
DESCRIPTION
DIMENSIONS
Split Repair Boot for Total Containment electrical conduit entry fittings 2.4x1.4  w/ Fill Tube
2.4x1.4
Split Repair Boot for Total Containment electrical conduit entry fittings 2.61x1.4  w/ Fill Tube
2.61x1.4
Split Repair Boot for Total Containment entry fittings. 6.8x2.0  w/ Fill Tube
6.8x2.0
Split Repair Boot for Total Containment entry fittings. 6.8x2.25  w/ Fill Tube
6.8x2.25
Split Repair Boot for Total Containment entry fittings. 6.8x2.5  w/ Fill Tube
6.8x2.5
Split Repair Boot for Total Containment entry fittings. 6.8x2.7  w/ Fill Tube
6.8x2.7
Split Repair Boot for Total Containment entry fittings. 6.8x3.0  w/ Fill Tube
6.8x3.0
Split Repair Boot for Total Containment entry fittings. 6.8x3.5  w/ Fill Tube
6.8x3.5
SBTCIF6.8x4.5
Split Repair Boot for Total Containment entry fittings. 6.8x4.5  w/ Fill Tube
6.8x4.5
       
.TCI Non-Split Repair Boots for Total Containment Fittings
PART NUMBER
DESCRIPTION
DIMENSIONS
Non-Split Repair Boot for Total Containment entry fittings. 6.8x2.0
6.8x2.0
Non-Split Repair Boot for Total Containment entry fittings. 6.8x2.0  w/ Air Test
6.8x2.0
Non-Split Repair Boot for Total Containment entry fittings. 6.8x2.25
6.8x2.25
Non-Split Repair Boot for Total Containment entry fittings. 6.8x2.25  w/ Air Test
6.8x2.25
Non-Split Repair Boot for Total Containment entry fittings. 6.8x2.5
6.8x2.5
Non-Split Repair Boot for Total Containment entry fittings. 6.8x2.5  w/ Air Test
6.8x2.5
Non-Split Repair Boot for Total Containment entry fittings. 6.8x2.7
6.8x2.7
Non-Split Repair Boot for Total Containment entry fittings. 6.8x3.0
6.8x3.0
Non-Split Repair Boot for Total Containment entry fittings. 6.8x3.0  w/ Air Test
6.8x3.0
Non-Split Repair Boot for Total Containment entry fittings. 6.8x3.5
6.8x3.5
Non-Split Repair Boot for Total Containment entry fittings. 6.8x3.5  w/ Air Test
6.8x3.5
Non-Split Repair Boot for Total Containment entry fittings. 6.8x4.5
6.8x4.5
TCI6.8x4.5A
Non-Split Repair Boot for Total Containment entry fittings. 6.8x4.5  w/ Air Test
6.8x4.5
     
.TCIF Non-Split Repair Boots with Fill Tube for Total Containment Fittings
PART NUMBER
DESCRIPTION
DIMENSIONS
Non-Split Repair Boot for Total Containment entry fittings. 6.8x2.0  w/ Fill Tube
6.8x2.0
Non-Split Repair Boot for Total Containment entry fittings. 6.8x2.25  w/ Fill Tube
6.8x2.25
Non-Split Repair Boot for Total Containment entry fittings. 6.8x2.5  w/ Fill Tube
6.8x2.5
Non-Split Repair Boot for Total Containment entry fittings. 6.8x2.7  w/ Fill Tube
6.8x2.7
Non-Split Repair Boot for Total Containment entry fittings. 6.8x3.0  w/ Fill Tube
6.8x3.0
Non-Split Repair Boot for Total Containment entry fittings. 6.8x3.5  w/ Fill Tube
6.8x3.5
Non-Split Repair Boot for Total Containment entry fittings. 6.8x4.5  w/ Fill Tube
6.8x4.5
   
Home | Company | Products | Installation | Training | Engineering Prints | Technical Data | Industry Links | News & Events | Contact Us